Tazi, Imam, Muthmainnah, Muthmainnah, Hananto, Farid Samsu ORCID: https://orcid.org/0000-0002-0305-5803 and Sasmitaninghidayah, Wiwis (2024) Development and prototyping of a concentrated ethanol gas monitoring system based on the MQ-3 sensor using the KAVi machine calibrator for environmental safety. Development and prototyping of a concentrated ethanol gas monitoring system based on the MQ-3 sensor using the KAVi machine calibrator for environmental safety, 7 (3). ISSN 2675-1240

[img] Text
20505.PDF - Published Version
Available under License Creative Commons Attribution Non-commercial No Derivatives.

Download (2MB)

Abstract

This research outlines the development of a device for measuring concentrated ethanol gas concentrations using the MQ-3 sensor. The device is engineered utilizing an Arduino Uno microcontroller and an LCD as the output interface. The MQ-3 sensor has demonstrated optimal sensitivity and a linear response to ethanol gas. The range of ethanol gas concentrations tested, from 10% to 70%, was selected to match the capabilities of the KAVi machine in generating ethanol gas. The testing process of the sensor was conducted to generate data that were subsequently calibrated to ensure measurement accuracy. Validation results indicate that the MQ-3 sensor can measure ethanol gas concentrations with high accuracy and good linearity within this range. However, discrepancies between the sensor measurements and the calibrator values were observed and need attention. The development of this device provides improvements in the accuracy and linearity of the MQ-3 sensor compared to previous studies. It is important to note that the KAVi machine has limitations in producing ethanol gas concentrations above 70%, which should be considered in the practical applications of this device. Overall, this device shows great potential in applications for monitoring ethanol gas concentrations, with a note to consider the limitations of the ethanol gas production process from the KAVi machine for more optimal results.

Item Type: Journal Article
Keywords: ethanol gas KAVi machine MQ-3 Sensor calibration
Subjects: 02 PHYSICAL SCIENCES > 0299 Other Physical Sciences > 029999 Physical Sciences not elsewhere classified
Divisions: Faculty of Mathematics and Sciences > Department of Physics
Depositing User: Farid Samsu Hananto
Date Deposited: 14 Oct 2024 15:05

Downloads

Downloads per month over past year

Origin of downloads

Actions (login required)

View Item View Item